A graded case is marked out of 100 from four decisions — the airway, the mode, the settings and the outcome — then adjusted for what happened while the patient was on the machine.

Where the 100 points come from

A graded case is scored out of 100 from four decisions. Each one is scored as a percentage of its own weight.

25Airway & escalationWhether the patient got the airway they needed.
15Ventilator modeWhether the mode suits this patient's physiology.
30Ventilator settingsHow close each dial sat to this patient's targets.
30Patient outcomeWhere the patient ended the case — with volume tolerance folded in for a patient who arrived dry.
Then added on or taken off
Escalating from non-invasive support to a definitive airway+5
Time spent in the danger zone− up to 20
An induction agent that works against the patient− up to 12
Each answer asked of Medical Control− 2 to 6, capped at 25
Left on the standard adult starting set — volume control, 6–8 mL/kg predicted body weight, rate 12–20, PEEP 5–8no lower than 80
Not surviving — death the clinician's own hand causedcapped at 25
Not surviving — a problem that was never acted oncapped at 45

The total is clamped between 0 and 100. Causing a death costs more than failing to prevent one: a run the clinician's own hand ended is capped lower than one where a problem was simply not acted on. The floor for the standard adult starting set is applied above those caps, so a patient who did not survive still fails the run however tidy the settings were.

How each decision is marked

Nothing here is a bare right or wrong. Every choice is scored on what it does to the patient in front of you.

Airway & escalation — 25 points

Escalating from non-invasive support to a tube adds 5 points on top of the total. Over-intubating is scaled by acuity: a dangerous arrival picture — hypoxic, tachypneic or hypercapnic — lifts the case one band.

The airway this patient needed100%
A tube in a critical patient, who might have been tried non-invasively first85%
A tube in a severe patient80%
A tube in a moderate patient70%
A tube in a very mild patient50%
Non-invasive support where the patient needed a tube30%
Ventilator mode — 15 points

A wrong mode also scales the settings score down with it, in proportion to how wrong it is — the right numbers delivered the wrong way are still the wrong numbers.

The recommended mode100%
A different mode in the same family of targeting85%
A different family, same class of support70%
The wrong class of support0%
Patient outcome — 30 points

For a patient who arrived dry, volume tolerance is folded into this figure: mean airway pressure beyond what their preload could carry is a worse outcome, however tidy the numbers looked.

Patient stabilized within targets100%
Patient survived but was not at target50%
Patient arrested but was resuscitated25%
The patient did not survive0%
Induction agent — costs up to 12 points

What a service stocks is not the clinician's decision, so only an agent that works against the patient's physiology is marked down hard.

The agent that suits this patient100%
An agent that will still get the tube in75%
An agent that works against the patient0%
Needle decompression — earns, or costs

Marked on whether the chest was under tension, not on whether the needle was used. The pneumothorax step of the DOPE checklist is the decompression itself, so it earns the same.

A tension pneumothorax released with a needle+5 points
A needle into a chest that was not under tension-8 points
Most that can be lost to unnecessary needles-16 points

How each setting is scored

Every control the running mode offers is scored against the case's own target, and the weighted average of those is the settings score. A value inside the full-credit tolerance earns all of it, and a near miss earns 40%.

What each setting is worth

Not every dial costs the same to get wrong. Tidal volume and the pressures that set it are where the harm is, so they carry the most; the oxygenation settings are corrected in seconds and carry the least.

Tidal Volume×4Insp. Pressure×3IPAP×3PEEP×2.5EPAP / PEEP×2.5Pressure Support×2Resp. Rate×2Backup Rate×2Inspir. Time×1.5Target Min Vent×1.5FiO2×1Trigger×1
Judged in the setting's own units
SettingFull creditNear miss
PEEP (cmH2O)±1±3
EPAP / PEEP (cmH2O)±1±3
Insp. Pressure (cmH2O)±3±6
IPAP (cmH2O)±2±5
Target Min Vent (L/min)±1±2.5
Inspir. Time (s)±0.2±0.5
Pressure Support (cmH2O)±3±6
Trigger (L/min)±0.5±2
Judged as a share of the target

A fixed number of units is a different error at every target — ten points of FiO2 is a large difference at 30% and almost nothing at 90%. These are judged proportionally instead, with a floor so a small target is not held to an impossible standard.

SettingFull creditNear miss
FiO2±12% (min ±4)±25% (min ±8)
Resp. Rate±10% (min ±1.5)±22% (min ±3)
Backup Rate±10% (min ±1.5)±22% (min ±3)
Tidal volume

Tidal volume is graded in steps rather than against one number. The case's own target is the ideal, but a lung of this size takes a range, so a volume near the target — or anywhere inside the patient's predicted 6–8 mL/kg band — is treated as defensible rather than wrong. It is also the single heaviest setting in the score.

Within 0 mL of the case's target100%
Within 20 mL of the case's target90%
Within 50 mL of the case's target80%
Anywhere else inside the patient's 6–8 mL/kg band75%
Outside that band0%

A near miss on any other setting earns 40% of its weight.

Grades, and the accuracy figure

The score becomes a letter grade. The debrief also reports accuracy — a separate figure that blends how well the case was run, without counting the outcome twice.

A
90 and above
B
80 – 89
C
70 – 79
D
60 – 69
F
below 60

A patient who does not survive is graded F whatever the score would have been, and the score itself is capped — at 25 when the death came from the clinician's own hand, and at 45 when it came from a problem that was there to be found and was not acted on. Causing a death costs more than failing to prevent one.

Accuracy — settings, mode, time at target, time clear
How close the settings sat to target40%
Whether the mode suited the physiology20%
The share of the case spent at target30%
The share of the case spent clear of the danger zone10%
At target

SpO2 within 2% of the case's target and EtCO2 within 4 mmHg of it, at the same moment.

In the danger zone

SpO2 more than 7% below target, EtCO2 more than 12 mmHg off it, or the patient no longer alive. The share of the case spent here is what the score is docked for, up to 20 points.

What isn't scored

These two run in the simulator like any other case but are never given a score or a grade.

Simulation (free play)

The patient never deteriorates and nothing is scored. You get the run report — what you changed, and what the gases did in answer.

A case set to be marked by hand

Its creator chose not to have it scored, so it ends as a practice run: the report, and no grade. Whoever is running the case judges it.

Where these numbers come from

The clinical targets a case is scored against come from the sources below — the tidal volumes, pressure limits, saturation windows and CO2 targets are drawn from published critical care practice. The weighting and tolerances on this page are this simulator's own design, built so a clinically sound run scores well.

Each case also carries its own citations — the specific sources its targets and recommended strategy were drawn from. Those appear on the debrief, and in the downloaded report.