ReVel

Simulation

Patient
Simulation — Normal Lungs

Healthy lungs — normal and , no and ordinary CO2 production. The baseline every other preset is measured against.

On arrival
HR
78bpm
RR
12/min
SpO2
98%
EtCO2
38mmHg
BP
118/72
What you see on arrival
    ReVel™
    Airway PressurecmH2O
    9080706050403020100
    PIP19cmH2O
    Vte500mL
    Min Vol6L/min
    Rate12/min
    ControlsScroll dial selects · turn to set
    Breath Mode
    Breath Type
    volume
    O2
    Sensitivity
    Patient Effort
    Effort
    Pres. Control--cmH2O
    Pres. Support--cmH2O
    AlarmsLimits
    Low Pk. Pres.12
    High Pres. Limit32
    Low FiO221
    Low Min. Vol3.0
    NPPV
    Active
    No active alarms
    Pulse Oximeter
    SpO299%
    High Alarm
    Low Alarm
    Pulse Rate78bpm
    High Alarm
    Low Alarm
    Signal
    Pulse Ox On / Off
    CareFusion
    On / Off
    Check
    Power
    External Power
    Battery Pack
    Transition Batt.
    Battery Charger
    Vent Inop
    Scroll
    Vt
    Control Lock
    Maneuvers
    Manual Breath
    Silence / Reset

    CareFusion ReVel · tap any ? for help

    Patient Monitor

    CARDIAC MONITORSINUS
    ECG78bpm
    SpO299%
    EtCO239mmHg
    NIBP118/72 (87) mmHg
    HR
    78bpm
    RR
    12/min
    SpO2
    99%
    EtCO2
    39mmHg
    BP
    118/72mmHg
    MAP
    87mmHg
    pH
    7.41
    Ppeak
    19cmH2O
    VTe
    500mL
    PEEP
    5 cmH2O
    FiO2
    50%
    MVe
    6 L/min
    Pmean
    8 cmH2O
    Auto-PEEP
    0 cmH2O
    Driving P
    10 cmH2O

    Patient

    Healthy

    Healthy lungs — normal compliance and resistance, no shunt and ordinary CO2 production. The baseline every other preset is measured against.

    Learn what each control does here before you take on a sick patient.

    Volume status

    Euvolemic
    dryeuvolemicoverloaded

    Normal preload. Tolerates the usual PEEP and inspiratory time without giving up cardiac output.

    Drag the bar, or pick a preset

    pH

    Normal
    7.41arterial
    acidoticnormalalkalotic

    Normal pH. The ventilator's own CO2 still moves the number either way from here.

    Pick a preset, or drag the bar
    Hypoventilate and retained CO2 pushes the pH down; hyperventilate and it climbs. Half of this number belongs to the ventilator.
    A preset puts the patient straight onto that pH and holds them there for a few seconds, so the number can be read before the ventilator answers. After that the respiratory half takes over — it comes from the patient's own CO₂, so changing the minute ventilation moves the pH with it.

    Simulation — Normal Lungs

    Healthy lungs — normal and , no and ordinary CO2 production. The baseline every other preset is measured against.

    Free-play simulation — nothing here is graded and the patient will not deteriorate. Change any control and watch the numbers respond.

    Learn what each control does here before you take on a sick patient.

    Alarms & Feedback

    No active alarms — ventilation within limits.

    For training and familiarization only. ReVel / CareFusion, ZOLL and Hamilton Medical are trademarks of their respective owners; this simulator is an independent training tool and is not affiliated with, sponsored by or endorsed by them. The simulated ventilators are not exact replicas of the real devices and the scenarios are teaching examples — errors and simplifications may be present. Always refer to the manufacturer's documentation for the device you actually use.

    For training & education only. Not for patient care. This project is a work in progress.ContactPrivacy PolicyTerms of Use